The Analysis of the Failure of 110 kV Circuit Tripping and Reclosing Under the Connection Mode of an Inner Bridge

More Information
  • Received Date: June 08, 2022
  • Through the 110 kV internal bridge wiring, only 110 kV line configuration voltage transformer, 110 kV line protection busbar voltage, line voltage access, analysis of recclosing mode, voltage parallel device switching switch mode, has a good practical significance to the operation and maintenance of equipment.

  • [1]
    北京四方继保自动化股份有限公司. CSC-161系列数字式线路保护装置说明书[M]. 2014.
    [2]
    长园深瑞继保自动化有限公司. ISA-358G备用电源自动投入装置说明书[M]. 2014.
    [3]
    国电南瑞科技股份有限公司. NSR65XRF-D00电压并列/切换装置技术使用说明书[M]. 2010.
  • Related Articles

    [1]YANG Liu, JIN Pu. Optimization Design of Voltage Switching Circuit for 110 kV Expanded Inner Bridge Connection[J]. RURAL ELECTRIFICATION, 2025, (1): 15-18. DOI: 10.13882/j.cnki.ncdqh.2407A046
    [2]LIANG Yuliang, LI Ming, ZHU Hai, FENG Jiecheng, LIU Nianqi, LU Jiayang. Analysis of False Trip of 110 kV Experimental Variable Differential Protection[J]. RURAL ELECTRIFICATION, 2024, (7): 89-90. DOI: 10.13882/j.cnki.ncdqh.2024.07.023
    [3]SUN Dezhou, ZHANG Quanyuan, DONG Zhanxiang, LIANG Zhilei, KANG Xintong. Analysis of No-load Closing Frequency Voltage Rise and Bus-side Disconnect Switch Phase A Ground Faults on 220 kV Line[J]. RURAL ELECTRIFICATION, 2024, (5): 46-52. DOI: 10.13882/j.cnki.ncdqh.2024.05.012
    [4]LIN Dingneng, JI Wenkui, ZHENG Yuande, CHEN Long, YING Yupeng, MA Xiulin. Cause Analysis and Circuit Improvement of Abnormal Reclosing Charging Lamp on 220 kV Line[J]. RURAL ELECTRIFICATION, 2024, (5): 41-45. DOI: 10.13882/j.cnki.ncdqh.2024.05.011
    [5]CHEN Pengyu, WANG Jing, ZHOU Xu. Analysis of an Abnormal 10 kV Bus Voltage Accident in a 110 kV Substation[J]. RURAL ELECTRIFICATION, 2023, (12): 99-100. DOI: 10.13882/j.cnki.ncdqh.2023.12.028
    [6]LIAO Tao, CAO Xiaolu, GAO Liming, ZHOU Mo, LUO Huiyong, WANG Guohui. Calculation and Analysis of Error Electricity Quantity Caused by Measurement Error Due to Voltage Switching Relay Failure[J]. RURAL ELECTRIFICATION, 2023, (1): 86-88. DOI: 10.13882/j.cnki.ncdqh.2023.01.023
    [7]Xia Xishan, Zhang Bin, Lv Kunlu. Operating Analysis Related to Unbalanced Voltage Protection in 3# Capacitor Bank Located 110 kV Substations[J]. RURAL ELECTRIFICATION, 2021, (8): 26-27. DOI: 10.13882/j.cnki.ncdqh.2021.08.007
    [8]Wang Guolin. Researches of Overvoltage due to 330 kV No-load Line Asynchronous Switching in[J]. RURAL ELECTRIFICATION, 2021, (7): 18-20. DOI: 10.13882/j.cnki.ncdqh.2021.07.005
    [9]Ying Xiaojuan, Wang Jingsheng. Analysis of Voltage Transformer Secondary Wiring Fusing in 10 kV 2# Bus-bar of 110/10 kV Transformer[J]. RURAL ELECTRIFICATION, 2020, (8): 36-37. DOI: 10.13882/j.cnki.ncdqh.2020.08.011
    [10]Liu Zhao, Li Xiaoxi, Wang Jiao, Liu Yangyang, Zhao Haixia. Defect Analysis of Capacity Grave Overload A 110 kV Capacitor Voltage Transformers[J]. RURAL ELECTRIFICATION, 2020, (4): 33-35. DOI: 10.13882/j.cnki.ncdqh.2020.04.010

Catalog

    Article views PDF downloads Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return