Advanced Search
GONG Zhuorui. Common Defects and Diagnosis Analysis of Complete Equipment of Shunt Capacitor[J]. RURAL ELECTRIFICATION, 2024, (6): 49-51, 68. DOI: 10.13882/j.cnki.ncdqh.2024.06.011
Citation: GONG Zhuorui. Common Defects and Diagnosis Analysis of Complete Equipment of Shunt Capacitor[J]. RURAL ELECTRIFICATION, 2024, (6): 49-51, 68. DOI: 10.13882/j.cnki.ncdqh.2024.06.011

Common Defects and Diagnosis Analysis of Complete Equipment of Shunt Capacitor

More Information
  • Received Date: August 14, 2023
  • Available Online: June 16, 2024
  • As a reactive power compensation device, shunt capacitor is widely used in the power network to improve the voltage quality and reduce the line losses. However, due to the large loads in summer results in frequent faults of shunt capacitors, most of them are protection trips caused by three-phase voltage imbalance. This article will provide cases analysis to illustrate several common fault causes, propose maintenance strategies, and make some suggests for the operation, maintenance, and repair of shunt capacitors in operation.

  • [1]
    任金鹏, 陶志良. 10 kV补偿电容器电压不平衡导致保护跳闸的原因分析[J]. 冶金动力,2023,(1):12−13,39.
    [2]
    张凯. 电容器组不平衡保护动作原因分析[J]. 科技与企业,2013(8):238,240.
  • Related Articles

    [1]LIN Jingzhuo. Application of Coiling and Tying Tool in Electric Power Operation[J]. RURAL ELECTRIFICATION, 2024, (5): 73-75. DOI: 10.13882/j.cnki.ncdqh.2024.05.019
    [2]LIU Yihua, QIU Shuang, XUE Sixiang, YAN Ding. Discussion on the Transformation Method and Common Problems of 10 kV Neutral Grounding Mode from Arc Suppression Coil to Small Resistance[J]. RURAL ELECTRIFICATION, 2024, (2): 26-29. DOI: 10.13882/j.cnki.ncdqh.2024.02.006
    [3]WANG Simeng, CHEN Dongwei, LI Xiaoyang, LEI Jinyue, LIU Chen, LI Zhen. Typical Case of Insulation Discharge Signal Defect Localization in Switchgear[J]. RURAL ELECTRIFICATION, 2023, (11): 30-33. DOI: 10.13882/j.cnki.ncdqh.2023.11.011
    [4]YU Zeyang, LI Yang, LI Jiawei, SHEN Yanbo. Development of Insulating Baffles for Discharge Clamping Insulators[J]. RURAL ELECTRIFICATION, 2022, (11): 56-57. DOI: 10.13882/j.cnki.ncdqh.2022.11.013
    [5]LEI Qiaohong, JU Chengshan. Calculation and Analysis of Protection Setting After Transformation of Arc Suppression Coil Parallelling Low Resistance in Substation[J]. RURAL ELECTRIFICATION, 2022, (8): 19-21. DOI: 10.13882/j.cnki.ncdqh.2022.08.005
    [6]DONG Jikang. Analysis of Power Loss Accident of 10 kV Bus Caused by Non Shutdown of Arc Suppression Coil[J]. RURAL ELECTRIFICATION, 2022, (5): 35-36. DOI: 10.13882/j.cnki.ncdqh.2022.05.009
    [7]Wu Wangye, Lu Yuqi. Research and Application of Inter-electrode Discharge Device for 10 kV Capacitor[J]. RURAL ELECTRIFICATION, 2021, (7): 50-51. DOI: 10.13882/j.cnki.ncdqh.2021.07.015
    [8]Lü Kunlu, Geng Yihui, Xia Xishan, Yan Xiaolong. Analysis of Cause of Frequent Burning of Closing Coil[J]. RURAL ELECTRIFICATION, 2020, (10): 34-34. DOI: 10.13882/j.cnki.ncdqh.2020.10.012
    [9]Sheng Yuan. Protective Device of Closing Coil of Circuit Breaker Operating Mechanism Based on Arduino[J]. RURAL ELECTRIFICATION, 2020, (8): 67-70. DOI: 10.13882/j.cnki.ncdqh.2020.08.021
    [10]Yang Youxing, Mo Shixun, Xie Rusong, Li Mei, Chen Zhanji, Lu Weihong, Zhang Mengying. Design Research of Automatic Tuning Petersen Coil Based on Flux Control[J]. RURAL ELECTRIFICATION, 2020, (7): 64-67. DOI: 10.13882/j.cnki.ncdqh.2020.07.022