YAN Qingfang, WU Yueren, WANG Tianjian, CHEN Lei. Metal Objects Picked up by High Winds Caused the Main Transformer Bushing to Fault[J]. RURAL ELECTRIFICATION, 2022, (2): 92-92. DOI: 10.13882/j.cnki.ncdqh.2022.02.029
Citation: YAN Qingfang, WU Yueren, WANG Tianjian, CHEN Lei. Metal Objects Picked up by High Winds Caused the Main Transformer Bushing to Fault[J]. RURAL ELECTRIFICATION, 2022, (2): 92-92. DOI: 10.13882/j.cnki.ncdqh.2022.02.029

Metal Objects Picked up by High Winds Caused the Main Transformer Bushing to Fault

More Information
  • Related Articles

    [1]LIANG Yuliang, YU Lei1, YANG Yixiong, YIN Bin, LI Ming. Analysis and Handling of a Main Transformer Trip Caused by Abnormal Weather[J]. RURAL ELECTRIFICATION, 2024, (12): 106-108. DOI: 10.13882/j.cnki.ncdqh.2401A026
    [2]WANG Song, CEN Rongjia. Analysis of Main Transformer Protetaion Ataion Caused by Distribution Network Line Heteronymous Phase Cross Country Fault[J]. RURAL ELECTRIFICATION, 2023, (8): 48-52. DOI: 10.13882/j.cnki.ncdqh.2023.08.011
    [3]HUANG Gang, DENG Demao, PENG Hongjin, WANG Kaibo, WANG Kun, JIN Jiwei. Analysis on an Accident of 110 kV Main Transformer Protection Action Caused by a Developmental Fault on a 110 kV Line[J]. RURAL ELECTRIFICATION, 2023, (7): 16-18. DOI: 10.13882/j.cnki.ncdqh.2023.07.005
    [4]LIU Zhao, YANG Bin, LIU Xiaoyan, WANG Jiao, TIAN Xiaolong. Analysis of Overheating Defect Caused by Loose Connection of Transformer Bushing Bolt[J]. RURAL ELECTRIFICATION, 2022, (11): 33-35. DOI: 10.13882/j.cnki.ncdqh.2022.11.007
    [5]An Ning, Sun Yan, Ma Zhenjing, Ma Qianli, Ma Yu, Wang Aili. A Main Transformer Damage due to 35kV Lines Oscillation Discharge[J]. RURAL ELECTRIFICATION, 2021, (8): 28-30. DOI: 10.13882/j.cnki.ncdqh.2021.08.008
    [6]Yang Jiachen, Tang Xianghua, Xu Zhouning, Zhao Xin, Shen Xin. Analysis on Abnormal Test Data of High Voltage Bushing of 110 kV Main Transformer[J]. RURAL ELECTRIFICATION, 2020, (11): 39-41. DOI: 10.13882/j.cnki.ncdqh.2020.11.012
    [7]Zhou Fuju, Shi Aixiang. Main Transformer CB Tripping Fault Analysis due to Multiple Circuit Lines Fault on Same Tower[J]. RURAL ELECTRIFICATION, 2020, (5): 78-79. DOI: 10.13882/j.cnki.ncdqh.2020.05.026
    [8]Zhou Xin, Tian Xin, Tang Zhenguo. Elimination Related to Temperature Abnormality Fault in Main Transformer Bushing[J]. RURAL ELECTRIFICATION, 2018, (2): 32-33. DOI: 10.13882/j.cnki.ncdqh.2018.02.010
    [9]Xiao Qiong. Main Transformer Insulation Fault Analysis and Maintenance Methods[J]. RURAL ELECTRIFICATION, 2017, (12): 24-26. DOI: 10.13882/j.cnki.ncdqh.2017.12.009
    [10]Chu Yanling, Gao Ming, Wang Jianjie, Zhang Jingping, Pan Jiale. A fault Analyses of Main Transformer Outage Due to Line Fault[J]. RURAL ELECTRIFICATION, 2017, (1): 22-23. DOI: 10.13882/j.cnki.ncdqh.2017.01.010

Catalog

    Article views PDF downloads Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return