Advanced Search

column
Speedily Up Push on Science and Technology Progress to Assist for Enterprise Across Development
Sun Modi
2012(11): 5-6. DOI: 10.13882/j.cnki.ncdqh.2012.11.003
Abstract PDF
Application Related to Five Preventive Measures System in Substation Central Control
Lv Guibin
2012(11): 7-7. DOI: 10.13882/j.cnki.ncdqh.2012.11.004
Abstract PDF
Analysis Scheme of Feasibility Study in Integrated on Line Observation System
Li Junqi
2012(11): 8-9. DOI: 10.13882/j.cnki.ncdqh.2012.11.005
Abstract PDF
Weak Point and Counter-fault Measure Related to Power Distribution Network Operation in County Level
Li Daofa, Hu Xiangang, Fan Huifang
2012(11): 10-12. DOI: 10.13882/j.cnki.ncdqh.2012.11.013
Abstract PDF
Measure and Recommendation Related to Power Network Voltage Administering in Oil Field
Zhang Fan, Bian Dongkui, Li Yangyang
2012(11): 13-14. DOI: 10.13882/j.cnki.ncdqh.2012.11.014
Abstract PDF
Problems of Reserve Power Source Automatic Throw-in Device in Duplicate Supply Application
Song Dawei
2012(11): 15-15. DOI: 10.13882/j.cnki.ncdqh.2012.11.006
Abstract PDF
Inquiry of Logic Principle Related to Reserve Power Source Automatic Throw-in Device in Multiple Supply System
Wang Dezhi
2012(11): 16-17. DOI: 10.13882/j.cnki.ncdqh.2012.11.007
Abstract PDF
Analysis of Condensed Dew and Moist Problem Related to10 kV Power Cables
Li Shoupeng
2012(11): 18-19. DOI: 10.13882/j.cnki.ncdqh.2012.11.015
Abstract PDF
Energy-saving System Based on LV on-Load Dynamic Balance Method
Li Mingtu, Yuan Miao
2012(11): 20-21. DOI: 10.13882/j.cnki.ncdqh.2012.11.016
Abstract PDF
Check Out and Influential Factors of Soil Resistivity in Shallow Soil Layer in Beijing Area
Ding Wanli, Ren Zhishan, Li Congyun
2012(11): 22-23. DOI: 10.13882/j.cnki.ncdqh.2012.11.017
Abstract PDF
Tripping Fault of 110 kV Main Transformer Result From Line Failure
Lei Qiaohong, Ju Chengshan
2012(11): 24-25. DOI: 10.13882/j.cnki.ncdqh.2012.11.018
Abstract PDF
Locking Out Design Related to LV Outgoing Lines for Transformers
Wu Wenshang, Su Aiguo, Qiu Yonghui
2012(11): 26-27. DOI: 10.13882/j.cnki.ncdqh.2012.11.020
Abstract PDF
Control Circuit Fault Due to Anti-pumping Function of Circuit Breakers
Zhao Lingjie, Zhu Ting
2012(11): 28-28. DOI: 10.13882/j.cnki.ncdqh.2012.11.021
Abstract PDF
Analysis and Preventive Serialization of Typical Examples Breaking Rule and Regulation in Rural Village Power System (11)
Liu Bingjiang, Liu Han
2012(11): 29-30. DOI: 10.13882/j.cnki.ncdqh.2012.11.001
Abstract PDF
Intelligently Integrated Control System for Area Supplied by Pole-mounted Distribution Transformer
Xu Xiaopeng, Zhan Keming, Li Yuan, Fa Zhi
2012(11): 31-32. DOI: 10.13882/j.cnki.ncdqh.2012.11.008
Abstract PDF
A New Type of Power-line Carrier Automatizating kWh Meter Reading System
Mei Houxi, Zhou Heping
2012(11): 33-34. DOI: 10.13882/j.cnki.ncdqh.2012.11.009
Abstract PDF
Achieving Remote Monitor to Integrated Automatic Substation Using Dispatch Data Network
Li Zhi
2012(11): 35-36. DOI: 10.13882/j.cnki.ncdqh.2012.11.022
Abstract PDF
Reconstruction and Upgrade for Power Communication Network in Qidong City
Cao Bin
2012(11): 37-38. DOI: 10.13882/j.cnki.ncdqh.2012.11.023
Abstract PDF
Settle Scheme Related to Dispatching Automation Spare Channel for Rural Village Power Network
Li Huanqiu, Zhang Hong
2012(11): 39-40. DOI: 10.13882/j.cnki.ncdqh.2012.11.024
Abstract PDF
Rise of Operating Ratio for Power Line Carrier Communication Equipment
Jin Shihao, Dong Ting
2012(11): 41-42. DOI: 10.13882/j.cnki.ncdqh.2012.11.025
Abstract PDF
Rise of Remote Signal Correct Rate for Automation Equipment
Pan Pengfei, Xu Fubin
2012(11): 43-43. DOI: 10.13882/j.cnki.ncdqh.2012.11.026
Abstract PDF
Installing Equipment Related to Current Transformer in Middle-position Switch-cabinet
Wu Zhimin
2012(11): 44-45. DOI: 10.13882/j.cnki.ncdqh.2012.11.027
Abstract PDF
New Method Related to Installing Small Size Impulse Water Turbine
Zhu Chaoxiao
2012(11): 46-46. DOI: 10.13882/j.cnki.ncdqh.2012.11.011
Abstract PDF
Analysis of Influence of Distributed Refrigeration, Heat Supply and Power Generation on Beijing Power Network
Zhang Di, Zhou Yunbin, Wang Liyong
2012(11): 47-49. DOI: 10.13882/j.cnki.ncdqh.2012.11.028
Abstract PDF
Analysis and Inquiry Related to Small Network Operating Mode for Small Size Hydroelectric Power Station
Wang Yongyi, Du Chuang, Wang Tianbao, Gao Kai
2012(11): 50-51. DOI: 10.13882/j.cnki.ncdqh.2012.11.012
Abstract PDF
Development of Preventive Electric Shock Wheelbarrow for Outgoing Line Repair in Middle-position Witch-cabinet
Liu Fei
2012(11): 52-53. DOI: 10.13882/j.cnki.ncdqh.2012.11.029
Abstract PDF
Technical Application Related to On-line Monitor Deviceand Fault Disconnector for Metal Oxide Surge Arrestors
Xiao Shiyan, Zhang Yanbin, Wang Peixin, Shi Shan
2012(11): 54-55. DOI: 10.13882/j.cnki.ncdqh.2012.11.030
Abstract PDF
Handling Method Related to Voltage Circuit Abnormality of 10 kV in 35 kV Substations
Zhou Xin, Zhou Xiaoyan, Zhang Yanhong, Wang Lin
2012(11): 56-56. DOI: 10.13882/j.cnki.ncdqh.2012.11.031
Abstract PDF
Attentive Matter of Short-circuit Fault Treatment for Transformer
Wan Hongwei
2012(11): 57-57. DOI: 10.13882/j.cnki.ncdqh.2012.11.032
Abstract PDF
Search Method to DC Earthing
Xu Ranran, Guo Hongwei
2012(11): 58-58. DOI: 10.13882/j.cnki.ncdqh.2012.11.033
Abstract PDF
Shallow Talking Related to How to Raise Power Supply Reliability
Liu Qingliang
2012(11): 59-59. DOI: 10.13882/j.cnki.ncdqh.2012.11.034
Abstract PDF
Rise of Examining Quality of Material Demand Plan Using Excel
Liu Ying, Lei Jing, Han Ying, Kang Yuqian
2012(11): 60-60. DOI: 10.13882/j.cnki.ncdqh.2012.11.010
Abstract PDF