ZHANG Xiang, LI Huiyong. Analysis of Two Cases of Relay Protection Missetting Resulting in Mistrip Accidents[J]. RURAL ELECTRIFICATION, 2023, (11): 39-40. DOI: 10.13882/j.cnki.ncdqh.2023.11.013
Citation: ZHANG Xiang, LI Huiyong. Analysis of Two Cases of Relay Protection Missetting Resulting in Mistrip Accidents[J]. RURAL ELECTRIFICATION, 2023, (11): 39-40. DOI: 10.13882/j.cnki.ncdqh.2023.11.013

Analysis of Two Cases of Relay Protection Missetting Resulting in Mistrip Accidents

More Information
  • Received Date: August 02, 2023
  • Available Online: November 07, 2023
  • The correct operation of the relay protection device is the prerequisite to ensure the safe and stable operation of the power system, and the missetting of the protection setting value will lead to the protection rejection or misoperation. This paper analyzes a case of missetting leading to an out-of-area fault trip and a case of missetting leading to load fluctuation leading to false trip of the circuit breaker, and discusses the causes of false trip of the circuit breaker. Finally put forward the prevention measures to prevent the recurrence of such incidents.

  • [1]
    谷国瑞. 误整定引发误跳闸[J]. 农村电工,2021,29(4):49. doi: 10.3969/j.issn.1006-8910.2021.04.043
    [2]
    肖明伟. 一起由误整定引发的发电机组跳闸事件分析[J]. 山东工业技术,2020(4):121−124. doi: 10.16640/j.cnki.37-1222/t.2020.04.021
    [3]
    周碎云,马秀林. 继电保护装置误整定引起的思考[J]. 大众用电,2017,32(12):28.
    [4]
    赖天德. 继电保护装置定值误整定探讨[J]. 电工技术,2017(8):91−92. doi: 10.3969/j.issn.1002-1388.2017.08.039
    [5]
    王飞,王志祥. 实例探讨继电保护定值误整定及预控措施[J]. 现代工业经济和信息化,2015,5(1):53−54,104. doi: 10.3969/j.issn.2095-0748.2015.01.018
  • Related Articles

    [1]CHEN Feng. Case Analysis of Tripping Caused by Missetting[J]. RURAL ELECTRIFICATION, 2025, (4): 39-41. DOI: 10.13882/j.cnki.ncdqh.2407A075
    [2]WANG Xiaoguang, WANG Zerui, WANG Ziqi, ZHAO Guankun. Analysis and Precontrol Measures of Protection Misoperation in 110 kV Low Resistance Grounding Substation[J]. RURAL ELECTRIFICATION, 2024, (7): 31-35. DOI: 10.13882/j.cnki.ncdqh.2024.07.007
    [3]ZHANG Qiuyi, LI Mengna, HU Heng. Impact of New Energy Power Plant Connection on Power Grid Relay Protection[J]. RURAL ELECTRIFICATION, 2024, (1): 41-44. DOI: 10.13882/j.cnki.ncdqh.2024.01.011
    [4]XIAN Jingjing. Analysis of Grounding Technology for Secondary System of Substation Relay Protection[J]. RURAL ELECTRIFICATION, 2023, (10): 24-26, 84. DOI: 10.13882/j.cnki.ncdqh.2023.10.007
    [5]GAO Chao. Typical Experience of Relay Protection Setting Calculation in 35 kV Substation[J]. RURAL ELECTRIFICATION, 2023, (1): 93-95. DOI: 10.13882/j.cnki.ncdqh.2023.01.026
    [6]CHEN Weihua, MA Xiulin, GUAN Shengchao, ZHANG Jing, YE Renjie, LI Mingyue, HUANG Zhen. A Protection False Action Analysis and Preventive Measures Caused by Abnormal Large Number of Merging Unit[J]. RURAL ELECTRIFICATION, 2022, (7): 27-30. DOI: 10.13882/j.cnki.ncdqh.2022.07.008
    [7]YUE Lianxing, WANG Jinping. Research on Fault Treatment of Distribution Network with the Cooperation of Relay Protection and Distribution Automation[J]. RURAL ELECTRIFICATION, 2022, (5): 26-27. DOI: 10.13882/j.cnki.ncdqh.2022.05.006
    [8]WANG Guolin, ZHANG Fan, YU Wei. Mal-operation Analysis on Cooling Control Power Failure Protection of 220 kV Transformer[J]. RURAL ELECTRIFICATION, 2022, (3): 23-24. DOI: 10.13882/j.cnki.ncdqh.2022.03.006
    [9]Zhang Zhen, Li Huangqiang, Yu Han, Ai Fei, Jiang Rong. Setting of Backup Protection Suited for 220 kV Transformers[J]. RURAL ELECTRIFICATION, 2017, (10): 29-30. DOI: 10.13882/j.cnki.ncdqh.2017.10.011
    [10]Lin Huixin, Li Wencheng. Reason Analysis and Preventive Counter Measure of Earthing Transformer Protection Incorrect Operation[J]. RURAL ELECTRIFICATION, 2016, (9): 32-33. DOI: 10.13882/j.cnki.ncdqh.2016.09.011
  • Cited by

    Periodical cited type(1)

    1. 陈峰. 误整定导致跳闸的案例分析. 农村电气化. 2025(04): 39-41 . 本站查看

    Other cited types(0)

Catalog

    Article views (23) PDF downloads (13) Cited by(1)

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return