Advanced Search
Ma Juan, Huang Jianzhong, Shi Yao. A Reason Analysis of False Closing Lockout Related to Voltage Time Type Sectionalizer[J]. RURAL ELECTRIFICATION, 2021, (4): 37-39. DOI: 10.13882/j.cnki.ncdqh.2021.04.012
Citation: Ma Juan, Huang Jianzhong, Shi Yao. A Reason Analysis of False Closing Lockout Related to Voltage Time Type Sectionalizer[J]. RURAL ELECTRIFICATION, 2021, (4): 37-39. DOI: 10.13882/j.cnki.ncdqh.2021.04.012

A Reason Analysis of False Closing Lockout Related to Voltage Time Type Sectionalizer

More Information
  • Received Date: December 20, 2020
  • Revised Date: February 23, 2021
  • [1]
    中国南方电网公司, 南方电网10 kV(20 kV)中压配电网继电保护整定原则(试行)[S], 2016.
    [2]
    侯惠芬, 黄建中. 电压型分段器得电未合闸的原因分析及改进[J]. 农村电气化, 2017(10).
    [3]
    黄建中. 远后备保护在电压-时间型配网自动化线路中的运用[J]. 农村电气化, 2019(11).
  • Related Articles

    [1]MA Pengxi, HUANG Jianzhong. Discussion on the Locking and Opening Function of Voltage Type Segmenter[J]. RURAL ELECTRIFICATION, 2023, (10): 12-16. DOI: 10.13882/j.cnki.ncdqh.2023.10.004
    [2]YAN Qingfeng. Risk Analysis and Improvement Scheme of DC Filter Protection Signal Maloperation[J]. RURAL ELECTRIFICATION, 2022, (8): 30-31. DOI: 10.13882/j.cnki.ncdqh.2022.08.008
    [3]LIU Ruigui, SONG Xianqin, WU Jihong, CHEN Dong, ZOU Li. Abnormal Analysis of Zero Sequence Current Acquisition of Distribution Switch in Rural Power Network and Application of Setting Calculation method of Zero Sequence Protection[J]. RURAL ELECTRIFICATION, 2022, (6): 13-17. DOI: 10.13882/j.cnki.ncdqh.2022.06.003
    [4]YANG Yao, ZHU Mimi. Configuration Principle Approaching of Power Distribution Network Section Switches[J]. RURAL ELECTRIFICATION, 2022, (4): 91-91. DOI: 10.13882/j.cnki.ncdqh.2022.04.023
    [5]ZHANG Minghui. The Analysis of Defect of GW16-252 Disconnector Closing[J]. RURAL ELECTRIFICATION, 2022, (2): 80-81. DOI: 10.13882/j.cnki.ncdqh.2022.02.024
    [6]Huang Jianzhong, Xia Shikong, Huang Liangliang, Ma Pengxi. Reason Analyses of Switch on Function Failure of Voltage Type Sectionalizer When Power Supply Recovery in a Power Supply Region[J]. RURAL ELECTRIFICATION, 2020, (10): 30-33. DOI: 10.13882/j.cnki.ncdqh.2020.10.011
    [7]Huang Jianzhong. Application of Remote Backup Relaying in Power Distribution Network Automation Lines with Voltage- time Type[J]. RURAL ELECTRIFICATION, 2019, (11): 22-24, 27. DOI: 10.13882/j.cnki.ncdqh.2019.11.006
    [8]Feng Yougang, Xiong Jie. Analysis of False Action of NotWork Protection in 220 kV Circuit Breaker Used for A Substation[J]. RURAL ELECTRIFICATION, 2018, (7): 35-36. DOI: 10.13882/j.cnki.ncdqh.2018.07.012
    [9]Liu Wanglai. On-line Leakage Current Measurement and Test for Surge Protector[J]. RURAL ELECTRIFICATION, 2018, (2): 28-29. DOI: 10.13882/j.cnki.ncdqh.2018.02.008
    [10]Liu Zongliang, Zhang Ting, Chen Yunqi. Application of Locking Technology of Distribution Ring Main Unit in Accident Prevention[J]. RURAL ELECTRIFICATION, 2017, (12): 15-17. DOI: 10.13882/j.cnki.ncdqh.2017.12.005

Catalog

    Article views PDF downloads Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return