Liu Xingyu, Guo Hua. Fault Analysis and Preventive Measure of 110 kV Transformers Light Buchholz Relay Alarm[J]. RURAL ELECTRIFICATION, 2020, (6): 37-39. DOI: 10.13882/j.cnki.ncdqh.2020.06.011
Citation: Liu Xingyu, Guo Hua. Fault Analysis and Preventive Measure of 110 kV Transformers Light Buchholz Relay Alarm[J]. RURAL ELECTRIFICATION, 2020, (6): 37-39. DOI: 10.13882/j.cnki.ncdqh.2020.06.011

Fault Analysis and Preventive Measure of 110 kV Transformers Light Buchholz Relay Alarm

More Information
  • Available Online: May 12, 2025
  • [1]
    王亚梦. 变压器轻瓦斯保护动作分析[J]. 农村电气化, 2019, 382(03): 76-76.
    [2]
    陈珉, 陈胜科, 詹江杨. 一起220 kV电流互感器油色谱异常事故分析及研究[J]. 变压器, 2018, 55(11): 84-87.
    [3]
    张云峰. 变压器瓦斯保护误动原因分析及应对措施[J]. 电网技术, 2008, 32(S2): 300-302.
    [4]
    黎瑛, 王国洲. 瓦斯继电器故障的分析及处理[J]. 农村电气化, 2011, 290(7): 21-21.
    [5]
    王忠毅, 严平. 主变轻瓦斯保护动作后的原因分析及处理[J]. 高电压技术, 2005, 31(5): 87-88.
    [6]
    邢志宏, 豆河伟, 李宝华. 110 kV变压器试验数据异常分析方法的探讨[J]. 变压器, 2018, 55(11): 80-83.
    [7]
    马雁, 王非, 郭琳. 主变瓦斯保护动作故障分析与处理[J]. 电网与清洁能源, 2014, 30(10): 46-48.
  • Related Articles

    [1]ZHANG Quanyuan, XIONG Chenxi, SUN Dezhou, DU Wei. Analysis of Transformer Gap Protection Action Caused by Permanent Single-Phase Fault on 220 kV Lines[J]. RURAL ELECTRIFICATION, 2024, (11): 75-78. DOI: 10.13882/j.cnki.ncdqh.2405A013
    [2]HUANG Xin, WU Di, SUN Ding, ZHANG Qirong. Cause Analysis and Preventive Measures of a 110 kV Transformer Trip Event[J]. RURAL ELECTRIFICATION, 2024, (10): 62-65. DOI: 10.13882/j.cnki.ncdqh.2401A002
    [3]LIU Zhao, TIAN Xiaolong, LIU Xiaoyan. Diagnosis and Analysis of a 35 kV Transformer High-voltage Winding Inter-turn Short-circuit Defect[J]. RURAL ELECTRIFICATION, 2023, (12): 17-19, 31. DOI: 10.13882/j.cnki.ncdqh.2023.12.005
    [4]HONG Yanjun. Analysis of Potential Safety Hazards and Preventive Measures of Transformer Bushing[J]. RURAL ELECTRIFICATION, 2023, (11): 21-22, 29. DOI: 10.13882/j.cnki.ncdqh.2023.11.008
    [5]LIU Shengjun, FENG Zhengjun, LIU Zhao, ZHENG Xiangang, QIAO Hongjun, GUO Huiyong. Diagnosis and Analysis of a 220 kV Transformer Winding Deformation Defect[J]. RURAL ELECTRIFICATION, 2023, (5): 17-20. DOI: 10.13882/j.cnki.ncdqh.2023.05.005
    [6]Huang Boyu, Sun Xiuguo, Yang Pengcheng, Chen Hao, Dong Lisheng, Shi Bingheng. Treatment and Analysis of DC Resistance Abnormality in 1# Transformer in a 110 kV Substation[J]. RURAL ELECTRIFICATION, 2021, (11): 29-30, 33. DOI: 10.13882/j.cnki.ncdqh.2021.11.009
    [7]Yang Jiachen, Tang Xianghua, Xu Zhouning, Zhao Xin. Analysis and Treatmeat of Abnormal Increase of Acetylene in 110kV Transformer Oil[J]. RURAL ELECTRIFICATION, 2021, (7): 32-35. DOI: 10.13882/j.cnki.ncdqh.2021.07.010
    [8]Sun Shaohong, Mao Xu. Fault Analysis of Direct-current Resistance Excelled Standard Related Transformers[J]. RURAL ELECTRIFICATION, 2020, (8): 74-75. DOI: 10.13882/j.cnki.ncdqh.2020.08.023
    [9]Guo Liang. Fault Investigation and Analysis of on-load Tap Changer in a 110 kV Transformer[J]. RURAL ELECTRIFICATION, 2020, (6): 33-36. DOI: 10.13882/j.cnki.ncdqh.2020.06.010
    [10]Wang Yameng. Analyses of Light Buchholz Relaying Operation due to Slight Fault Gas in Transformers[J]. RURAL ELECTRIFICATION, 2019, (3): 74-74. DOI: 10.13882/j.cnki.ncdqh.2019.03.023

Catalog

    Article views PDF downloads Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return